TECMAR
WANGTEK 5150ES (33678-XXX VER.2)
|
Device Type |
Internal Tape Drive |
|
Interface |
SCSI |
|
Format |
QIC-120, QIC-150 (write) QIC-24, QIC-120, QIC-150 (read) |
|
Sustained Transfer Rate |
1800KBPS |
|
Size |
5.25 in. half height |
|
View |
Bottom |

|
CONNECTIONS |
|
|
Function |
Label |
|
Ground connector |
CN1 |
|
USER CONFIGURABLE SETTINGS |
|||
|
Setting |
Label |
Position |
|
|
» |
Ground connector enabled |
E2 |
Closed |
|
|
Ground connector disabled |
E2 |
Open |
|
» |
Factory configured - do not alter |
E5 |
Closed |
|
» |
Factory configured - do not alter |
E20/0 |
Open |
|
» |
Factory configured - do not alter |
E20/1 |
Open |
|
» |
Factory configured - do not alter |
E20/2 |
Open |
|
» |
Factory configured - do not alter (Diagnostic test connector) |
J32 |
Open |
|
DRIVE SELECT ID |
|||
|
Drive ID |
J10/A |
J10/B |
J10/C |
|
0 |
Open |
Open |
Open |
|
1 |
Closed |
Open |
Open |
|
2 |
Open |
Closed |
Open |
|
3 |
Closed |
Closed |
Open |
|
4 |
Open |
Open |
Closed |
|
5 |
Closed |
Open |
Closed |
|
6 |
Open |
Closed |
Closed |
|
7 |
Closed |
Closed |
Closed |
|
Note: The function of jumper J10/D is unidentified. It is factory configured and should not be altered. |
|||
|
TERMINATION POWER SELECTION |
||
|
Setting |
E1 |
|
|
» |
TERMPWR supplied by drive |
Closed |
|
|
TERMPWR supplied by SCSI interface to drive |
Open |
|
MANUFACTURERS RECOMMENDED MEDIA |
|
|
Tape |
Capacity |
|
DC 600A |
125 MB (in QIC-120 mode) |
|
DC 6150 |
150 MB (in QIC-150 mode) |
|
DC 6250 |
250 MB (in QIC-150 mode) |
|
DIAGNOSTIC LED(S) |
|
Note: Function and location of LED(s) is/are unidentified. |
|
MISCELLANEOUS TECHNICAL NOTES |
|
Termination is enabled or disabled via the three terminating resistors (see diagram). |