TRANSITION NETWORKS
E-FRL-MC04, E-FRL-MC04(SM), E-FRL-MC04(L)
|
Card Type |
Ethernet Transceiver |
|
NIC Type |
Ethernet |
|
Maximum Onboard Memory |
Unidentified |
|
Boot ROM |
Not available |
|
Network Transfer Rate |
10Mbps |
|
Topology |
Linear Bus, Star |
|
Wiring Type |
AUI transceiver via DB-15 port, Fiber optic cable |
|
Data Bus |
External |
|
CONNECTIONS | |||
|
Function |
Label |
Function |
Label |
|
AUI transceiver via DB-15 |
CN1 |
Fiber optic - ST transmit |
CN3 |
|
Fiber optic - ST receive |
CN3 | ||
|
USER CONFIGURABLE SETTINGS | ||
|
Function |
Label |
Position |
|
SQE enabled |
SW1 |
On |
|
SQE disabled |
SW1 |
Off |
|
Full duplex mode enabled |
SW2 |
On |
|
Half duplex mode enabled |
SW2 |
Off |
|
DIAGNOSTIC LED(S) | |||
|
LED |
Color |
Status |
Condition |
|
LED1 |
Red |
On |
Jabber detected on network |
|
LED1 |
Red |
Off |
No jabber detected on network |
|
LED2 |
Red |
Blinking/On |
Collision detected on network |
|
LED2 |
Red |
Off |
No collision detected on network |
|
LED3 |
Green |
Blinking/On |
Data is being transmitted |
|
LED3 |
Green |
Off |
Data is not being transmitted |
|
LED4 |
Green |
Blinking/On |
Data is being received |
|
LED4 |
Green |
Off |
Data is not being received |
|
LED5 |
Green |
On |
Network connection is good |
|
LED5 |
Green |
Off |
Network connection is broken |
|
LED6 |
Green |
On |
Receiving power |
|
LED6 |
Green |
Off |
Not receiving power |
|
MISCELLANEOUS TECHNICAL NOTES |
|
The E-FRL-MC04 uses 850mn multi-mode fiber cable, the E-FRL-MC04(SM) uses 1300mn single-mode fiber cable, and the E-FRL-MC04(L) uses 1300mn multi-mode fiber cable. |