ADDTRON TECHNOLOGY COMPANY, LTD.
AE-200LC
| NIC Type | Ethernet | 
| Transfer Rate | 10Mbps | 
| Data Bus | 16-bit ISA | 
| Topology | Linear Bus | 
| Wiring Type | Unshielded twisted pair RG-58A/U 50ohm coaxial | 
| Boot ROM | Available | 

| I/O BASE ADDRESS | |||
| Address | JP1A | JP1B | |
| » | 300h | Open | Open | 
| 
 | 320h | Closed | Open | 
| 
 | 340h | Open | Closed | 
| 
 | 360h | Closed | Closed | 
| INTERRUPT REQUEST | |||||||
| IRQ | JP2A | JP2B | JP2C | JP2D | JP2E | JP2F | JP2G | 
| 2 | Closed | Open | Open | Open | Open | Open | Open | 
| 3 | Open | Closed | Open | Open | Open | Open | Open | 
| 4 | Open | Open | Closed | Open | Open | Open | Open | 
| 5 | Open | Open | Open | Closed | Open | Open | Open | 
| 10 | Open | Open | Open | Open | Closed | Open | Open | 
| 11 | Open | Open | Open | Open | Open | Closed | Open | 
| 12 | Open | Open | Open | Open | Open | Open | Closed | 
| BOOT ROM ADDRESS | |||||
| Address | JP3A | JP3B | JP3C | JP3D | |
| » | Disabled | Open | Open | Open | Open | 
| 
 | C8000h | Closed | Open | Closed | Open | 
| 
 | CC000h | Closed | Closed | Closed | Open | 
| 
 | D0000h | Closed | Open | Open | Closed | 
| 
 | D4000h | Closed | Closed | Open | Closed | 
| 
 | D8000h | Closed | Open | Closed | Closed | 
| 
 | DC000h | Closed | Closed | Closed | Closed | 
| COMPATIBILITY MODE | ||
| Setting | JP4 | |
| » | Enabled | Pins 1 & 2 closed | 
| 
 | Disabled | Pins 2 & 3 closed | 
| Note: On some systems the data bus timing is not truly IBM PC/AT compatible. If the card does not initialize or you receive an "Error Reading Address PROM" message, compatibility mode should be enabled. | ||
| CABLE TYPE | ||
| Type | JP5 | |
| » | RG-58A/U 50ohm coaxial | Pins 2 & 3 closed | 
| 
 | Unshielded twisted pair | Pins 1 & 2 closed | 

| DIAGNOSTIC LED(S) | |||
| LED | Color | Status | Condition | 
| LED1 | Red | Off | data is not being transmitted/received | 
| LED1 | Red | On | data is being transmitted/received | 
| LED2 | Green | On | 10BaseT link integrity exists | 
| LED2 | Green | Off | 10BaseT link integrity broken | 
| Note: LED2 is only functional when link integrity is enabled, and when installed on a 10BaseT network. | |||