DATA TECHNOLOGY CORPORATION
DTC6282-24
|
|
Data bus: 16-bit, ISA
Size: Half-length, full-height card
Hard drives supported: Two ESDI drives
Floppy drives supported: Four 360KB, 720KB, 1.2MB, or 1.44MB
|
CONNECTIONS | |
|
Function |
Location |
|
34-pin data cable connector-floppy drive |
J1 |
|
34-pin control cable connector-hard drive |
J2 |
|
20-pin data cable connector-drive 0 |
J3 |
|
20-pin data cable connector-drive 1 |
J4 |
|
4-pin connector-drive active LED |
J5 |
|
BIOS ADDRESS | ||
|
Address |
W1/jumper 1 |
W1/jumper 2 |
|
C800h |
open |
open |
|
D000h |
closed |
open |
|
D800h |
open |
closed |
|
D400h |
closed |
closed |
|
USER CONFIGURABLE SETTINGS | |||
|
Function |
Location |
Setting | |
| » |
BIOS enabled |
W1/jumper 3 |
closed |
|
BIOS disabled |
W1/jumper 3 |
open | |
| » |
Initial interrupt enabled after reset |
W1/jumper 4 |
closed |
|
Initial interrupt disabled after reset |
W1/jumper 4 |
open | |
| » |
Floppy drive uses standard logic |
W1/jumper 5 |
closed |
|
Floppy drive uses reverse logic
|
W1/jumper 5 |
open | |
| » |
Standard AT cable selected |
W1/jumper 6 |
open |
|
IBM cable selected |
W1/jumper 6 |
closed | |
| » |
Normal IRQ timing |
W2/jumper 8 |
open |
|
IRQ delay (40 m |
W2/jumper 8 |
closed | |
| » |
Floppy drive enabled |
W2/jumper 9 |
open |
|
Floppy drive disabled |
W2/jumper 9 |
closed | |
| » |
Auto deselect disabled |
W2/jumper 10 |
open |
|
Auto deselect enabled |
W2/jumper 10 |
closed | |
| » |
Hard drive port address is 1F0-1F7h |
W2/jumper 11 |
closed |
|
Hard drive port address is 170-177h
|
W2/jumper 11 |
open | |
| » |
Floppy drive precomp is scaled by data rate: 500KHz=125ns;300KHz=208ns;250KHz=250ns |
W3 |
pins 1 & 2 open |
|
Floppy drive precompensation is 125ns |
W3 |
pins 1 & 2 closed | |
| » |
Single speed floppy drives |
W3 |
pins 3 & 4 open |
|
Dual speed floppy drives |
W3 |
pins 3 & 4 closed | |
|
INTERRUPT REQUEST | |||
|
IRQ |
W2/jumper 12 |
W2/jumper 13 | |
| » |
Hard Drive Interrupt Request is IRQ14 |
open |
closed |
|
Hard Drive Interrupt Request is IRQ15 |
closed |
open | |
|
MISCELLANEOUS TECHNICAL NOTES |
|
W2/jumpers 1 through 7, and W2/jumpers 14 through 18 are Not used. |